Logo

The Athena X-ray Observatory: Community Support Portal

This web portal uses third-party cookies to track visits to the website only, no personal information is collected.

By continuing to use the site you are agreeing to our use of cookies. Learn more

I understand

Use of cookies

This website uses Google Analytics, a web analytics service provided by Google, Inc. (“Google”). Google Analytics uses “cookies”, which are text files placed on your computer, to help the website analyze how users use the site. The information generated by the cookie about your use of the website (including your IP address) will be transmitted to and stored by Google on servers in the United States. The IP address will be truncated before transmission. On our behalf Google will use this information for the purpose of evaluating your use of the website, compiling reports on website activity and providing other services relating to website activity and internet activity in connection with the use of the website. Google will not associate your IP address with any other data held by Google.

If you do not wish to receive a cookie, or if you wish your browser to notify you when you receive a cookie, you may use the option on your web browser to disable cookies. Click on the 'help' section of your browser to learn how to change cookie preferences.

180427ECucchettiAbstract: "With its array of 3840 Transition Edge Sensors (TESs), the Athena X-ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV up to 7 keV) from 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in systematic errors in the absolute energy scale. We plan to monitor such changes at pixel level via onboard X-ray calibration sources and correct the energy scale accordingly using a linear or quadratic interpolation of gain curves obtained during ground calibration. However, this may not be sufficient to meet the 0.4 eV accuracy required for the X-IFU. In this contribution, we introduce a new two-parameter gain correction technique, based on both the pulse-height estimate of a fiducial line and the baseline value of the pixels. Using gain functions that simulate ground calibration data, we show that this technique can accurately correct deviations in detector gain due to changes in TES operating conditions such as heat sink temperature, bias voltage, thermal radiation loading and linear amplifier gain. We also address potential optimisations of the onboard calibration source and compare the performance of this new technique with those previously used."

Read full document.

Papers related with Athena

Your Athena related publications: Please inform us about your Athena related publications. They will posted in our web site and in the Athena social media.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

Overview papers

  • 1

Athena mission proposal and white paper

  • 1

Athena supporting papers

  • 1
  • 2
  • 3